Skip to content

Search is only available in production builds. Try building and previewing the site to test it out locally.

J255 · Climatronic Control Module

Name
Climatronic Control Module
Type
control module / relay
Models
B6 and B7
Diagrams
7

Location

Integrated with Interior Temperature Sensor Fan -V42- and Instrument Panel Interiormanual text Manual pages 1172

Other location statements (3)
  • Centre console, in or at the A/C control headinferred from name
  • Wired into the instrument panel wiring harnessinferred from wiring
  • Its wires run through T6d (Connector station - LF seat wiring)inferred from wiring

Area: Instrument panel

Articles

Pins

One row per pin and wire colour; the pin opens the page of its wire, traced across every sheet. "Connects to" lists the other pins on the same circuit within a diagram; splices and ground points it passes are under "via". The function says how it was worked out: stated by the manual, derived from terminal markings, fuses or the colour code. "Not stated" means the manual only shows what the wire connects.

Pins printed without a connector code likely Sensors & Motors/actuators

PinWireFunctionConnects toModelsSheets
A/1
bl/sw 0.35 mm²
not statedV158/5B7 only419
A/10
ge/gn 0.35 mm²
not statedV71/6B7 only418
A/11
ge/bl 0.35 mm²
not statedV159/5B7 only419
A/12
or 0.35 mm²
ws/bl
not statedV159/6B7 only419
A/2
gn/ro 0.35 mm²
not statedV158/6B7 only419
A/3
ws/gr 0.35 mm²
not statedV107/6B7 only419
A/4
gr/gn 0.35 mm²
not statedV107/5B7 only419
A/5
ge 0.35 mm²
not statedV70/6B7 only418
A/6
ws/ge 0.35 mm²
not statedV70/5B7 only418
A/7
li/ge 0.35 mm²
not statedV113/6B7 only418
A/8
bl/ro 0.35 mm²
not statedV113/5B7 only418
A/9
ws/gn 0.35 mm²
not statedV71/5B7 only418
B/1
sw 0.35 mm²
5 Voltsstated
G112/3, G113/3, G135/3, G143/3, G220/3, G221/3
via L31
B7 only418
B/10
gn 0.35 mm²
not statedG89/2B7 only420
B/11
ro/sw 0.35 mm²
not statedG263/2B7 only420
B/14
br/ws 0.35 mm²
Ground (terminal 31)stated
G112/1, G113/1, G143/1
via 97
B7 only418
B/2
ws/bl 0.35 mm²
not statedG220/2B7 only419
B/3
gr/bl 0.35 mm²
not statedG221/2B7 only419
B/4
gr 0.35 mm²
not statedG135/2B7 only419
B/5
gr/ge 0.35 mm²
not statedG112/2B7 only418
B/6
gn/ws 0.35 mm²
not statedG143/2B7 only418
B/7
gr/gn 0.35 mm²
not statedG113/2B7 only418
B/8
gr/ro 0.35 mm²
not statedG261/2B7 only420
B/9
bl 0.35 mm²
not statedG262/2B7 only420
C/1
ro/br 0.35 mm²
not statedG150/2B7 only420
C/11
or/gn 0.35 mm²
Comfort CAN Highstated
J527/9, J285/17, J136/9, J345/I/3, J364/I/8, J386/4, J387/4, J388/4, J389/4, J393/13, J446/14, J503/1 and 2 more
via A146
B6 and B7365 372 424 715
C/12
or/br 0.35 mm²
Comfort CAN Lowstated
J527/8, J285/18, J136/10, J345/I/4, J364/I/7, J386/5, J387/5, J388/5, J389/5, J393/12, J446/7, J503/2 and 2 more
via A147
B6 and B7365 372 424 715
C/13
ge/sw 0.35 mm²
Load-reduction positive (terminal 75, off while cranking)stated
D/2/75
via A33
B7 only417
C/2
li/br 0.35 mm²
not statedG151/2B7 only420
C/3
ws/gn 0.35 mm²
not statedG107/4B7 only420
C/4
sw/gn 0.35 mm²
not statedG107/1B7 only420
C/5
br/sw 0.5 mm²
sw/ws
not statedB6 and B7366 373 735
C/5
sw/ws 0.5 mm²
not statedB7 only424
C/6
br/sw 0.5 mm²
ge/bl
not statedB6 and B7367 374 736
C/6
ge/bl 0.5 mm²
not statedB7 only424
C/7
br/li 0.35 mm²
not statedG238/3B7 only421
C/8
ws/ge 0.5 mm²
not statedA14/1B7 only422
D/1
ro/ge 0.35 mm²
not statedG107/2B7 only420
D/11
gn/ro 0.35 mm²
K-line (diagnosis)stated
J285/23
via A76
B7 only424
D/12
ro/bl 1.0 mm²
Fused supply from S1 (10 A, terminal 30) to J255 Climatronic Control Modulederived
S1/1aB7 only417 453 672
D/13
br 1.0 mm²
Ground (terminal 31) at 33 (Behind instrument panel, right)stated
via 238
B7 only417
D/16
br/ws 0.35 mm²
Sensor groundstated
G107/3, G150/1, G151/1
via 244
B6 and B7367 374 420 736
D/3
bl/br 0.5 mm²
not statedN280/2B7 only421
D/5
sw/br 0.5 mm²
not statedJ126/2B7 only423
D/6
ge 0.5 mm²
not statedJ126/1B7 only423
D/7
br/bl 0.35 mm²
not statedG65/2B7 only422
F/1
sw/ge 1.0 mm²
sw/gn
not statedB6 and B7366 373 735
F/1
sw/gn 1.0 mm²
not statedB7 only424
F/2
sw/ge 1.0 mm²
not statedB6 and B7367 374 424 736
F/3
ro/ws 2.5 mm²
Battery positive, permanent (terminal 30), fused by S226 (30 A, terminal 30)derived
Battery positive, permanent (terminal 30), fused by S226 (30 A, terminal 30)stated
S244/44a, J215/1, J216/1, S226/44a
via O1
B6 and B7365 372 417 735
F/6
sw/ro 0.5 mm²
not statedJ9/6B7 only423 453 672

Diagrams

From the factory manual Audi A4 Wiring Diagrams and Component Locations, edition 12.2005, extracted automatically. Check anything important against the PDF sheet.