Skip to content

Search is only available in production builds. Try building and previewing the site to test it out locally.

Ground (terminal 31)

Net n5a607c05 · one diagram

Function
Ground (terminal 31)stated
Basis: ground connection 97
Wire
br/ws
Models
B7 only
Drawn in
1 diagram, 4 stretches
Checked
Not checked by hand. Extracted from the manual automatically.

What is on this wire

Parts (4)

  • G112pin 1Central Flap Motor Position Sensor
  • G113pin 1Back Pressure Flap Motor Position Sensor
  • G143pin 1Recirculation Flap Motor Position Sensor
  • J255pin B/14Climatronic Control Module

Grounds (1)

  • 97Ground Connection 1 (in A/C wiring harness)

Where these parts are

PartLocation
G112Part of Central Air Flap Motor -V70-manual text p. 1173
G113Part of Air Flow Flap Motor -V71-manual text p. 1173
G143Part of Recirculation Flap Motor -V113-manual text p. 1173
J255Integrated with Interior Temperature Sensor Fan -V42- and Instrument Panel Interiormanual text p. 1172
97Splice inside the A/C wiring harnesssheet legend

Drawing

Wires are br/ws (brown/white) unless a colour is written on them. 5 parts and points, 4 connections.

A schematic of the connections, drawn by this site from the traced wire: not the layout of the sheets. Red-edged boxes are the supply side. Parts appear once with every pin this wire touches; splices, grounds and inline connectors once per diagram (their codes repeat between diagrams). A wire that continues through a reference box or an unnamed joint is one line. Not shown: what is inside the parts (fuse elements, relay contacts, switches). Dashed lines are uncertain links; dashed red boxes are ends the extraction could not resolve. Tap a line for its stretch below, its colour for the sheet.

Stretch by stretch

Every stretch of this wire as the sheets draw it: one block per diagram, one table per sheet. The track number opens the stretch on the drawn sheet.

56 · Automatic Climate Control B7 · 4 stretches

Diagram 56 page

Page 418manual · Central Air Flap Motor, Air Flow Flap Motor, Recirculation Flap Motor

TrackWireFromToNotes
33br/ws 0.35 mm²ground 97G143 1
34br/ws 0.35 mm²ground 97G112 1
38br/ws 0.35 mm²ground 97G113 1
42br/ws 0.35 mm²J255 B/14ground 97

From the factory manual Audi A4 Wiring Diagrams and Component Locations, edition 12.2005, extracted automatically. Check anything important against the PDF sheet.