Skip to content

Search is only available in production builds. Try building and previewing the site to test it out locally.

Ground (terminal 31)

Net n4e6812d1 · joined across diagrams

Function
Ground (terminal 31)stated
Basis: ground connection 97
Wire
br/swbr/ws
Models
B6 only
Drawn in
2 diagrams, 22 stretches
Checked
Not checked by hand. Extracted from the manual automatically.

3 joins between diagrams, 1 not certain3 stretches to check2 guessed components

What is on this wire

Parts (11)

  • E87pin B/14A/C Control Head
  • G89pin 1Fresh Air Intake Duct Temperature Sensor
  • G112pin 1Central Flap Motor Position Sensor
  • G113pin 1Back Pressure Flap Motor Position Sensor
  • G135pin 1Defroster Flap Motor Position Sensor
  • G143pin 1, pin 3Recirculation Flap Motor Position Sensor
  • G220pin 1Left Temperature Flap Potentiometer/Actuator
  • G221pin 1Right Temperature Flap Potentiometer/Actuator
  • G261pin 1guessLeft Footwell Vent Temperature Sensor
  • G262pin 1Right Footwell Vent Temperature Sensor
  • G263pin 1guessEvaporator Vent Temperature Sensor

Grounds (1)

  • 97Ground Connection 1 (in A/C wiring harness)

Where these parts are

PartLocation
E87Centre console, in or at the A/C control headinferred from name
G89Wired into the A/C wiring harnessinferred from wiring
G112Part of Central Air Flap Motor -V70-manual text p. 1173
G113Part of Air Flow Flap Motor -V71-manual text p. 1173
G135Part of Defroster Flap Motor -V107-manual text p. 1173
G143Part of Recirculation Flap Motor -V113-manual text p. 1173
G220Part of Left Temperature Flap Motor -V158-manual text p. 1172
G221Wired into the A/C wiring harnessinferred from wiring
G261Footwell, under the instrument panelinferred from name
G262Footwell, under the instrument panelinferred from name
G263Wired into the A/C wiring harnessinferred from wiring
97Splice inside the A/C wiring harnesssheet legend

Drawing

br/sw 0.35 mm² · 1 stretch on page 291br/sw 0.35 mm² · 1 stretch on page 291br/sw 0.35 mm² · 1 stretch on page 291br/sw → br/ws 0.35 mm² · 1 stretch on page 291Show on the sheet (page 291)br/sw→br/wsbr/sw 0.35 mm² · 1 stretch on page 292br/sw 0.35 mm² · 1 stretch on page 292br/sw 0.35 mm² · 1 stretch on page 292br/sw 0.35 mm² · 1 stretch on page 293no colour printed 0.35 mm² · 1 stretch on page 293no colour printed 0.35 mm² · 1 stretch on page 293no colour printed 0.35 mm² · 1 stretch on page 293br/sw 0.35 mm² · 1 stretch on page 976br/sw 0.35 mm² · 1 stretch on page 976br/sw 0.35 mm² · 1 stretch on page 976br/sw 0.35 mm² · 1 stretch on page 976br/sw 0.35 mm² · 1 stretch on page 977br/sw 0.35 mm² · 1 stretch on page 977br/sw 0.35 mm² · 1 stretch on page 977br/sw 0.35 mm² · 1 stretch on page 978 · guessed partbr/sw 0.35 mm² · 1 stretch on page 978br/sw 0.35 mm² · 1 stretch on page 978br/sw 0.35 mm² · 1 stretch on page 978 · guessed partGround 97 · Ground Connection 1 (in A/C wiring harness)97G143 · Recirculation Flap Motor Position Sensor · pins 1, 3G1431, 3G112 · Central Flap Motor Position Sensor · pin 1G1121G113 · Back Pressure Flap Motor Position Sensor · pin 1G1131E87 · A/C Control Head · pin B/14E87B/14G135 · Defroster Flap Motor Position Sensor · pin 1G1351G220 · Left Temperature Flap Potentiometer/Actuator · pin 1G2201G221 · Right Temperature Flap Potentiometer/Actuator · pin 1G2211G261 · Left Footwell Vent Temperature Sensor · pin 1G2611G262 · Right Footwell Vent Temperature Sensor · pin 1G2621G89 · Fresh Air Intake Duct Temperature Sensor · pin 1G891G263 · Evaporator Vent Temperature Sensor · pin 1G2631Ground 97 · Ground Connection 1 (in A/C wiring harness)97

Wires are br/sw (brown/black) unless a colour is written on them. 13 parts and points, 22 connections.

A schematic of the connections, drawn by this site from the traced wire: not the layout of the sheets. Red-edged boxes are the supply side. Parts appear once with every pin this wire touches; splices, grounds and inline connectors once per diagram (their codes repeat between diagrams). A wire that continues through a reference box or an unnamed joint is one line. Not shown: what is inside the parts (fuse elements, relay contacts, switches). Dashed lines are uncertain links; dashed red boxes are ends the extraction could not resolve. Tap a line for its stretch below, its colour for the sheet.

Stretch by stretch

Every stretch of this wire as the sheets draw it: one block per diagram, one table per sheet. The track number opens the stretch on the drawn sheet.

  • guess: the component label is not right at the symbol; the part was assigned by position.
  • check: the extraction marked the stretch for a look at the sheet.
34 · Automatic Climate Control B6 · 11 stretches

Diagram 34 page · joined to other diagrams at G112/1, G135/1, G261/1medium

Page 291manual · Central Air Flap Motor, Air Flow Flap Motor, Recirculation Flap Motor

TrackWireFromToNotes
19br/sw 0.35 mm²ground 97G143 1
20br/sw 0.35 mm²ground 97G112 1
24br/sw 0.35 mm²ground 97G113 1
28br/sw → br/ws 0.35 mm²E87 B/14ground 97

Page 292manual · Defroster Flap Motor, Left Temperature Flap Motor, Right Temperature Flap Motor

TrackWireFromToNotes
30br/sw 0.35 mm²ground 97G135 1
34br/sw 0.35 mm²ground 97G220 1
38br/sw 0.35 mm²ground 97G221 1

Page 293manual · Sunlight Photo Sensor, Vent Temperature Sensor, Fresh Air Intake Duct Temperature Sensor

TrackWireFromToNotes
43br/sw 0.35 mm²G261 1ground 97
45no colour 0.35 mm²G262 1ground 97check
47no colour 0.35 mm²G89 1ground 97check
49no colour 0.35 mm²G263 1ground 97check
317 · Automatic Climate Control B6 · 11 stretches

Diagram 317 page · joined to other diagrams at G112/1, G135/1, G261/1medium

Page 976manual · A/C Control Head, central Air Flap, Air Flow Flap, Recirculation Flap

TrackWireFromToNotes
19br/sw 0.35 mm²ground 97G143 3
20br/sw 0.35 mm²ground 97G112 1
24br/sw 0.35 mm²ground 97G113 1
28br/sw 0.35 mm²E87 B/14ground 97

Page 977manual · A/C Control Head, defroster flap, temperatur flap

TrackWireFromToNotes
30br/sw 0.35 mm²ground 97G135 1
34br/sw 0.35 mm²ground 97G220 1
38br/sw 0.35 mm²ground 97G221 1

Page 978manual · A/C Control Head, Vent Temperature Sensor, Sunlight Photo Sensor, Fresh Air Intake Duct Temperature Sensor

TrackWireFromToNotes
43br/sw 0.35 mm²G261 1guessground 97
45br/sw 0.35 mm²G262 1ground 97
47br/sw 0.35 mm²G89 1ground 97
49br/sw 0.35 mm²G263 1guessground 97

From the factory manual Audi A4 Wiring Diagrams and Component Locations, edition 12.2005, extracted automatically. Check anything important against the PDF sheet.