Skip to content

Search is only available in production builds. Try building and previewing the site to test it out locally.

Fused supply from S16 (5 A, terminal 15) to J530 Garage Door Opener Control Module

Net n4bf54669 · joined across diagrams

Function
Fused supply from S16 (5 A, terminal 15) to J530 Garage Door Opener Control Modulederived
Basis: net hangs on the output side of S16
Wire
sw/ro
Models
B6 only
Drawn in
2 diagrams, 4 stretches
Checked
Not checked by hand. Extracted from the manual automatically.

1 join between diagrams

What is on this wire

Supply (1)

Fuses, the battery, alternator, ignition switch, and pins marked with a supply terminal (30, 15, 75, X, 50, 87).

Parts (1)

  • J530pin 4Garage Door Opener Control Module

Inline connectors (4)

  • T6mpin 46-Pin Connector, on the Garage Door Opener Control Head
  • T10ipin 910-Pin Connector, blue, connector station A-pillar, left
  • T10xpin 910-Pin Connector, black, near front bumper
  • T17gpin 1117-Pin Connector, dark brown, connector station A-pillar, left

Where these parts are

PartLocation
J530In the front bumper covermanual text p. 1330
S16Fuse panel at the left end of the instrument panel, fuse No. 16manual text p. 1114 p. 1118
T6mOn the Garage Door Opener Control Headsheet legend
T10iOn lower left A-pillar, behind trimmanual text p. 1100 p. 1101
T10xNear front bumpersheet legend
T17gOn lower left A-pillar, behind trimmanual text p. 1101

Drawing

Wires are sw/ro (black/red) unless a colour is written on them. 12 parts and points, 12 connections.

A schematic of the connections, drawn by this site from the traced wire: not the layout of the sheets. Red-edged boxes are the supply side. Parts appear once with every pin this wire touches; splices, grounds and inline connectors once per diagram (their codes repeat between diagrams). A wire that continues through a reference box or an unnamed joint is one line. Not shown: what is inside the parts (fuse elements, relay contacts, switches). Dashed lines are uncertain links; dashed red boxes are ends the extraction could not resolve. Tap a line for its stretch below, its colour for the sheet.

Stretch by stretch

Every stretch of this wire as the sheets draw it: one block per diagram, one table per sheet. The track number opens the stretch on the drawn sheet.

32 · Garage Door Opener - "Homelink" B6 · 2 stretches

Diagram 32 page · joined to other diagrams at S16/16a

Page 280manual · Garage Door Opener Control Head, Garage Door Opener Control Module, Fuse

TrackWireFromToNotes
20sw/ro 0.5 mm²S16 16ajoint
27sw/ro 0.35 / 0.5 mm²S16 16aJ530 4
333 · Garage Door Opener - "Homelink" B6 · 2 stretches

Diagram 333 page · joined to other diagrams at S16/16a

Page 1080manual · Garage Door Opener Control Head, Garage Door Opener Control Module, Fuse

TrackWireFromToNotes
20sw/ro 0.5 mm²S16 16ajoint
27sw/ro 0.35 mm²S16 16aJ530 4

From the factory manual Audi A4 Wiring Diagrams and Component Locations, edition 12.2005, extracted automatically. Check anything important against the PDF sheet.