Skip to content

Search is only available in production builds. Try building and previewing the site to test it out locally.

Wire between A14 and E87 (+1)

Net ne617a25e · joined across diagrams

Function
A14 Windshield Heating Voltage Converter — line to E87 A/C Control Head C/8endpoints only
Basis: named after the two parts it connects
Wire
ws/ge
Models
B6 only
Drawn in
2 diagrams, 2 stretches
Checked
Not checked by hand. Extracted from the manual automatically.

1 join between diagrams

What is on this wire

Parts (2)

  • A14pin 1Windshield Heating Voltage Converter
  • E87pin C/8A/C Control Head

Inline connectors (1)

  • T10cpin 910-Pin Connector, violet, connector station A-pillar, left

Where these parts are

PartLocation
A14Its wires run through T2n (Near Windshield Heating Voltage Converter)inferred from wiring
E87Centre console, in or at the A/C control headinferred from name
T10cOn lower left A-pillar, behind trimmanual text p. 1100 p. 1101

Drawing

Wires are ws/ge (white/yellow) unless a colour is written on them. 4 parts and points, 4 connections.

A schematic of the connections, drawn by this site from the traced wire: not the layout of the sheets. Red-edged boxes are the supply side. Parts appear once with every pin this wire touches; splices, grounds and inline connectors once per diagram (their codes repeat between diagrams). A wire that continues through a reference box or an unnamed joint is one line. Not shown: what is inside the parts (fuse elements, relay contacts, switches). Dashed lines are uncertain links; dashed red boxes are ends the extraction could not resolve. Tap a line for its stretch below, its colour for the sheet.

Stretch by stretch

Every stretch of this wire as the sheets draw it: one block per diagram, one table per sheet. The track number opens the stretch on the drawn sheet.

34 · Automatic Climate Control B6 · 1 stretch

Diagram 34 page · joined to other diagrams at E87/C/8

Page 294manual · A/C Control Head, high Pressure sensor, sensor for air quality, Compressor Regulator Valve, heated front window

TrackWireFromToNotes
67ws/ge 0.5 mm²E87 C/8A14 1
via T10c/9
317 · Automatic Climate Control B6 · 1 stretch

Diagram 317 page · joined to other diagrams at E87/C/8

Page 979manual · A/C Control Head, high Pressure sensor, sensor for air quality, Compressor Regulator Valve, heated front window

TrackWireFromToNotes
67ws/ge 0.5 mm²E87 C/8A14 1
via T10c/9

From the factory manual Audi A4 Wiring Diagrams and Component Locations, edition 12.2005, extracted automatically. Check anything important against the PDF sheet.